Frontpage Frontpage
Synchrotron

Danfysik is a leading supplier of equipment for synchrotron light sources, and you will find our products installed at most of the synchrotron facilities world wide.

Print this page Previous page

Booster booklet

Our supplies include:

  • Turn-key delivery of Pre-injectors and Booster Rings
  • Storage Ring, Booster Ring and beam transport line magnets
  • Kickers and septum magnets
  • Vacuum systems
  • Support and girder systems
  • DC or pulsed magnet power supplies
  • Insertion devices


Since 1997 Danfysik has delivered the following Turn-key accelerator systems:
  • The 500 MeV booster synchrotron included 53MeV Race Track Microtron - ANKA
  • Pre-injector for the ANKA Synchrotron, Germany - ANKA
  • The 2.9 GeV booster synchrotron for the Canadian Light Source - CLS

 


53 MeV RACE TRACK MICROTRON
The first electron accelerator of major size from Danfysik, a Race Track Microtron, has been delivered and installed at customer's site. The Danfysik Race Track Microtron is a high efficiency electron accelerator featuring:

  • High Compactness
  • Low energy spread
  • Low energy spread
  • Low beam emittance
  • Ease in operation

The Race Track Microtron consists of an electron gun, which injects into a 70 keV linac.
The energy gain per passage of the linac is 5.3 MeV which means that the beam will pass 10 times before it is extracted at the full energy, 53 MeV by means of a septum magnet.

Electron Energy 53 MeV
Pulse Current: 10 mA
Pulse Length: 1 µs
Pulse Repetition Rate: 0 - 10 Hz
Energy Spread: 0.3 %
RF Frequency: ~ 0.3 mmmrad
2.9986 GHz
Race Track Microtron for ANKA