The Beam Diagnostic Instrumentation System 5000 provides potential users with a line of diagnostics including both mechanics and associated electronics

Description

The Beam Diagnostic Instrumentation, System 5000, is based on a development at the Hahn-Meitner-Institute, Berlin and provides potential users with a complete line of beam diagnostic instrumentation from Danfysik, including both mechanics and associated electronics.

The program includes the following components

  • Water Cooled Slit 563
  • Faraday Cup 568
  • Water cooled Actuator 566

Basic criteria considered in the design of the components are

  • High vacuum - 10-7 Torr - all metal seals
  • Designed for heavy ion beams with 1000 W beam power
  • Wide dynamic range
  • Fast and reliable control
  • Tune up times kept to a minimum
  • Direct pick-up of beam currents on BPM and Faraday Cups
  • Components fit standard CF housings
  • Flanging NW 100 CF or NW 150 as standard